R.O. DRINKING WATER SYSTEM
MODEL T.F.C. - 435
INSTALLATION, OPERATION & SERVICE MANUAL
IMPORTANT NOTICES:
This reverse osmosis system contains replaceable treatment components critical for effective performance. It is the user's
responsibility to, and the manufacturer strongly recommends that the user, periodically test the product water to verify the system is
performing satisfactorily. See the test kit(s) for sampling instructions.
This system is acceptable for treatment of inuent concentrations of no more than 27 mg/L nitrate and 3 mg/L nitrite in
combination measured as N and is certied for nitrate/nitrite reduction only for water supplies with a pressure of 280 kPa (40 psig)
or greater.
This system conforms to NSF/ANSI Standard 58 for pentavalent arsenic reduction. See the Performance Data Sheet and Arsenic
Facts section for an explanation of reduction performance.
DO NOT USE WITH WATER THAT IS MICROBIOLOGICALLY UNSAFE OR OF UNKNOWN QUALITY,
WITHOUT ADEQUATE DISINFECTION BEFORE OR AFTER THE SYSTEM.
Systems certied for cyst reduction may be used on disinfected water that may contain lterable cysts.
Drink With Condence!
Tested and Certified by NSF International against
NSF/ANSI Standard 58 for the reduction of the claims
specied on the Performance Data Sheet.
MICROLINE
®
Vue de la page 0
1 2 3 4 5 6 ... 19 20

Résumé du contenu

Page 1 - MODEL T.F.C. - 435

R.O. DRINKING WATER SYSTEMMODEL T.F.C. - 435INSTALLATION, OPERATION & SERVICE MANUALIMPORTANT NOTICES:This reverse osmosis system contains replace

Page 2 - TABLE OF CONTENTS

102. Use a battery powered or properly grounded drill. Using the Clamp port as a drill guide, drill a 7/32" hole through the wall of the drain

Page 3 - See Page 10

11proper connections. The “Out” port on the In–Line Filter should be toward the faucet. Firmly press in the tubing. The ttings will grab the tubing

Page 4 - QUALITY MONITOR SEE EXPLODED

12 When the Faucet is rst opened, expect air and carbon nes (very ne black powder) from the In–Line and Activated Carbon Post Filters to be rinsed

Page 5

13•Attheendof15minutes,inthefollowingorder, close the Feed Water Saddle Valve, close the Holding Tank Valve and open the Dispensing Faucet to

Page 6

14SECTION VI. TROUBLE SHOOTING GUIDEProblem Possible Cause SolutionLow quantity of Product Water from Holding TankFeed Water Saddle Valve is plugged

Page 7

15Problem Possible Cause SolutionHigh Total Dissolved Solids (TDS) in the Product Water (continued)The Product Water and Drain Water lines are reverse

Page 8

16MADE IN USAEXPLODED VIEW & PARTS LIST19A ...Water Quality Test Kit23 ...Nitrate/Nitrite Test Kit12345678910111213141821201516

Page 9

17DRAWING NO. PART NO. DESCRIPTION 1... S2009 ... Self Tapping Screw 2...

Page 11

19NOTES:

Page 12

TABLE OF CONTENTS PageSECTION I. INTRODUCTION ...3SECTION II. SPECIFIC

Page 13

Form No. S1299-07Updated 2/26/20104462 Duraform Lane • Windsor • WI 53598-9716 Phone (608) 846-3010www.microlinero.comR.O. DRINKING WATER SYSTEMFIVE/O

Page 14

3SECTION I. INTRODUCTION Your new Reverse Osmosis (R.O.) Drinking Water System uses a combination of ltration technologies to reduce unwanted con

Page 15

4OPTIONAL T.F.C.–435 BASEMENT INSTALLATION DIAGRAM DISPENSING FAUCETPRODUCT(3/8” Blue)NOTE: FOR REFRIGERATOR WATER DISPENSER OR ICE MAKER HOOKUP, TEE

Page 16 - MADE IN USA

5 WATER QUALITY MONITOR–The optional Water Quality Monitor has been integrated into the system cover for instant monitoring at the touch of a button.

Page 17 - POST FILTER

6SECTION III. PREPARATION A. Major System Components The following components comprise the R.O. Drinking Water System. (Refer to Fig. 1, for genera

Page 18

73. R.O. Manifold Assembly–The manifold can be installed on either the right or left side of the under–sink area or a cabinet. The right side is reco

Page 19

83. Assemble the 1/8” Screws & Toggle Wings into the Faucet Base. Adjust the Wings approximately 1” plus the thickness of the mounting surface

Page 20 - Phone (608) 846-3010

92b. To install on (hard) steel or brass tubing supply line. •Thesupplylineshouldnowbedrained.Useabattery powered or properly grounded drill